{"id":1712,"date":"2017-09-27T08:35:05","date_gmt":"2017-09-27T08:35:05","guid":{"rendered":"http:\/\/v2.banadaran.net\/?page_id=1712\/"},"modified":"2017-09-27T08:44:27","modified_gmt":"2017-09-27T08:44:27","slug":"most-common-mistakes-made-by-roofers-part-3","status":"publish","type":"page","link":"http:\/\/banadaran.net\/en\/articles\/most-common-mistakes-made-by-roofers-part-3\/","title":{"rendered":"Most common mistakes made by roofers \u2013 part 3"},"content":{"rendered":"<div  class=\"fusion-fullwidth fullwidth-box fusion-blend-mode nonhundred-percent-fullwidth\"  style='background-color: rgba(255,255,255,0);background-position: center center;background-repeat: no-repeat;padding-top:20px;padding-bottom:20px;'><div class=\"fusion-builder-row fusion-row \"><div  class=\"fusion-layout-column fusion_builder_column fusion_builder_column_1_1  fusion-one-full fusion-column-first fusion-column-last 1_1\"  style='margin-top:0px;margin-bottom:20px;'>\r\n\t\t\t\t\t<div class=\"fusion-column-wrapper\" style=\"background-position:left top;background-repeat:no-repeat;-webkit-background-size:cover;-moz-background-size:cover;-o-background-size:cover;background-size:cover;\"  data-bg-url=\"\">\r\n\t\t\t\t\t\t<p>The installation of a shingles roof is a very critical part of your building or renovation project. You must use shingles of high quality and follow the\u00a0correct application guidelines. If you don\u2019t follow guidelines, you might up with a lot of problems.<\/p>\n<p>The past few weeks we already showed you 10 problems you can face on your roof (blog\u00a0<a href=\"\/en\/articles\/most-common-mistakes-made-by-roofers-part-1\/\" target=\"_blank\" rel=\"noopener\">part 1<\/a>\u00a0and\u00a0<a href=\"\/en\/articles\/most-common-mistakes-made-by-roofers-part-2\/\" target=\"_blank\" rel=\"noopener\">part 2<\/a>). Today we will take a look at the following 5 mistakes:<\/p>\n<ul>\n<li>Insufficient or non-existent attic ventilation<\/li>\n<li>No intakes or plugged soffit ventilation<\/li>\n<li>Mixed ventilation<\/li>\n<li>Installing shingles over old wooden boards<\/li>\n<li>Not mixing shingles<\/li>\n<\/ul>\n<p><strong>11.Insufficient or non-existent attic ventilation<\/strong><\/p>\n<p>When the attic is improperly vented you reduce air movement or have no movement at all. This usually increases moisture content. Under these conditions, heat builds up and shortens the life of your shingles roof. Moisture builds up, causing sheathing movement and deterioration, resulting in shingle failure. These circumstances are a major cause of a shorter life of the shingles roof.<\/p>\n<p><strong>Solution:<\/strong><\/p>\n<p>Cut exhaust openings for spot vents or ridge ventilation. Install proper ventilation to provide airflow circulation through the roofing structure.<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-1721\" src=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-01-300x195.jpg\" alt=\"\" width=\"300\" height=\"195\" srcset=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-01-200x130.jpg 200w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-01-300x195.jpg 300w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-01-400x260.jpg 400w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-01.jpg 404w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><br \/>\nMissing ventilation<\/p>\n<p>&nbsp;<\/p>\n<p><strong>12.No intakes or plugged soffit ventilation<\/strong><\/p>\n<p>Even though your soffit vents appear perforated from the exterior of the home, it is very important to make sure that air is flowing through them and into the attic. Often homeowners (and even professionals) will accidentally cover over their soffits with insulation. This can trap moisture in your attic and lead to condensation problems. Having adequate intake ventilation is equally as important as the exhaust ventilation.<\/p>\n<p><strong>Solution<\/strong><strong>:<\/strong><\/p>\n<p>In order to free up the airflow, remove insulation from the roof inlets at the eaves. If these intake air openings don\u2019t exist, precut them and install grilles for air circulation.<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-1723\" src=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-02-300x180.jpg\" alt=\"\" width=\"300\" height=\"180\" srcset=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-02-200x120.jpg 200w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-02-300x180.jpg 300w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-02-400x241.jpg 400w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-02.jpg 404w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><strong>13.Mixed ventilation<\/strong><\/p>\n<p>Each type of vent is designed to work and handle air flow in its own particular way. Air is intended to travel from the soffit at the eaves to the exhaust vents at the peak. Different vents draw air differently and combining vent types can decrease the efficiency of the ventilation and increase the energy bills. A simple example: if you combine a turbine vent with static vents, the turbine will takes airflow not from the soffit but from the nearest spot vent. This causes unwanted moisture and even snow can appear in the attic.<\/p>\n<p><strong>Solution<\/strong><strong>:<\/strong><\/p>\n<p>Plug\/close all unnecessary vents from inside of the attic. Always try to keep the top vents and cancel the lower vents by plugging them to create a free airflow from the soffit up to the ridge.<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-1725\" src=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-03-300x186.jpg\" alt=\"\" width=\"300\" height=\"186\" srcset=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-03-200x124.jpg 200w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-03-300x186.jpg 300w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-03-400x249.jpg 400w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-03.jpg 404w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><br \/>\nKeep the top vents<\/p>\n<p>&nbsp;<\/p>\n<p><strong>14.Installing shingles over old wooden boards<\/strong><\/p>\n<p>Roofers are commonly using the existing roofing deck regardless of the type or condition that it is in. Specifically in the case of old spaced board decking, this can cause major problems. When expansion and contraction occur, shingles will buckle. This will create gaps in the roofing system making it susceptible to water entry. If your roof deck is old or in poor condition it is always recommended that you cover the complete surface with an approved decking such as OSB or plywood boards. This will provide a stronger hold for the shingles and a better roofing system.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Solution<\/strong><strong>:<\/strong><\/p>\n<p>Try to repair buckles and waved shingles by pulling out the nails first. Then trim the shingles close to joints and nail them again. Secure these spot also with\u00a0<a href=\"\/en\/accessories\/iko-mastic\/\" target=\"_blank\" rel=\"noopener\">Shingle Stick<\/a>. If this repair doesn\u2019t help and shingles are buckling again, start to think about reroofing with a new deck made from OSB or plywood.<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-1727\" src=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-04-300x226.jpg\" alt=\"\" width=\"300\" height=\"226\" srcset=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-04-200x150.jpg 200w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-04-300x226.jpg 300w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-04-400x301.jpg 400w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-04.jpg 404w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><br \/>\nUse of old wooden boards can lead to buckling.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>15.Not mixing shingles<\/strong><\/p>\n<p>Always mix shingles from different bundles to avoid color blocks on the finished roof! Different batches of the same shingle can have a slightly different shade, so don\u2019t mix two production dates on the same side of the roof.<\/p>\n<p><strong>Solution<\/strong><strong>:<\/strong><\/p>\n<p>There is no solution for this mistake.\u00a0 After some time these color blocks will partly disappear when shingles are exposed to the weather conditions.<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-medium wp-image-1729\" src=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-05-300x226.jpg\" alt=\"\" width=\"300\" height=\"226\" srcset=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-05-200x150.jpg 200w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-05-300x226.jpg 300w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-05-400x301.jpg 400w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-05.jpg 404w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><br \/>\n<strong>Always\u00a0<\/strong>mix shingles!<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-full wp-image-1731\" src=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-06.jpg\" alt=\"\" width=\"603\" height=\"404\" srcset=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-06-200x134.jpg 200w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-06-300x201.jpg 300w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-06-400x268.jpg 400w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-06-600x402.jpg 600w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-06.jpg 603w\" sizes=\"(max-width: 603px) 100vw, 603px\" \/><\/p>\n<p><a href=\"\/en\/accessories\/iko-ventilation\/armourvent-multi-multi-plus\/\" target=\"_blank\" rel=\"noopener\"><strong>IKO ARMOURVENT MULTI \/ MULTI PLUS<\/strong><\/a><\/p>\n<p><strong>IKO Armourvent Multi and Multi Plus are\u00a0ventilation systems that provide\u00a0you a fabulous roof without visible\u00a0appliances. The unique design consists of a thin but ultra-strong\u00a0profile ensuring a smooth, straight and virtually&#8230;<\/strong><\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-full wp-image-1713\" src=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-07.jpg\" alt=\"\" width=\"603\" height=\"404\" srcset=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-07-200x134.jpg 200w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-07-300x201.jpg 300w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-07-400x268.jpg 400w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-07-600x402.jpg 600w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-07.jpg 603w\" sizes=\"(max-width: 603px) 100vw, 603px\" \/><\/p>\n<p><a href=\"\/en\/accessories\/iko-ventilation\/armourvent-ridge-plus\/\"><strong>IKO ARMOURVENT RIDGE PLUS<\/strong><\/a><\/p>\n<p><strong>IKO Armourvent Ridge Plus is designed to ensure a smooth straight roofline; thanks to\u00a0its internal baffle system, it keeps out rain, snow, leaves and\u00a0insects.<\/strong><\/p>\n<p><strong>IKO ventilation on your roof offers&#8230;<\/strong><\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-full wp-image-1715\" src=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-08.jpg\" alt=\"\" width=\"603\" height=\"404\" srcset=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-08-200x134.jpg 200w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-08-300x201.jpg 300w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-08-400x268.jpg 400w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-08-600x402.jpg 600w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-08.jpg 603w\" sizes=\"(max-width: 603px) 100vw, 603px\" \/><\/p>\n<p><a href=\"\/en\/accessories\/iko-ventilation\/armourvent-standard-special\/\"><strong>IKO ARMOURVENT STANDARD \/ SPECIAL<\/strong><\/a><\/p>\n<p><strong>Armourvent Standard<\/strong><strong>\u00a0is a\u00a0plastic and large size vent\u00a0allowing a high\u00a0degree of ventilation.\u00a0<\/strong><\/p>\n<p><strong>Armourvent\u00a0Special<\/strong><strong>\u00a0is a\u00a0trendy vent\u00a0in plastic designed in such a\u00a0way that they are hardly noticeable on a shingle\u00a0roof. The&#8230;<\/strong><\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-full wp-image-1717\" src=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-09.jpg\" alt=\"\" width=\"603\" height=\"404\" srcset=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-09-200x134.jpg 200w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-09-300x201.jpg 300w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-09-400x268.jpg 400w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-09-600x402.jpg 600w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-09.jpg 603w\" sizes=\"(max-width: 603px) 100vw, 603px\" \/><\/p>\n<p><strong>IKO AIRHAWK TURBINEVENT<\/strong><\/p>\n<p><strong>The\u00a0Airhawk Turbinevent\u00a0is used for ventilating large roof surface. It is an all aluminium\u00a0construction with maintenance-free top.<\/strong><\/p>\n<p><strong>IKO ventilation on your roof offers quite some\u00a0benefits:\u200b<\/strong><\/p>\n<ul>\n<li><strong>Extend the life <\/strong>of your roof<\/li>\n<\/ul>\n<p>&#8230;<\/p>\n<p><img loading=\"lazy\" class=\"alignnone size-full wp-image-1719\" src=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-10.jpg\" alt=\"\" width=\"603\" height=\"404\" srcset=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-10-200x134.jpg 200w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-10-300x201.jpg 300w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-10-400x268.jpg 400w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-10-600x402.jpg 600w, http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-10.jpg 603w\" sizes=\"(max-width: 603px) 100vw, 603px\" \/><\/p>\n<div class=\"fusion-clearfix\"><\/div>\r\n\r\n\t\t\t\t\t<\/div>\r\n\t\t\t\t<\/div><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":1312,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v14.4.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Most common mistakes made by roofers \u2013 part 3 - BANADARAN ASR IKO<\/title>\n<meta name=\"robots\" content=\"index, follow\" \/>\n<meta name=\"googlebot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta name=\"bingbot\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/banadaran.net\/\u0645\u0642\u0627\u0644\u0627\u062a\/\u0627\u0634\u062a\u0628\u0627\u0647\u0627\u062a-\u0631\u0627\u06cc\u062c-\u0646\u0635\u0627\u0628\u0627\u0646-\u0647\u0646\u06af\u0627\u0645-\u0646\u0635\u0628-\u0642\u0633\u0645\u062a-\u0633\u0648\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Most common mistakes made by roofers \u2013 part 3 - BANADARAN ASR IKO\" \/>\n<meta property=\"og:url\" content=\"http:\/\/banadaran.net\/\u0645\u0642\u0627\u0644\u0627\u062a\/\u0627\u0634\u062a\u0628\u0627\u0647\u0627\u062a-\u0631\u0627\u06cc\u062c-\u0646\u0635\u0627\u0628\u0627\u0646-\u0647\u0646\u06af\u0627\u0645-\u0646\u0635\u0628-\u0642\u0633\u0645\u062a-\u0633\u0648\/\" \/>\n<meta property=\"og:site_name\" content=\"BANADARAN ASR IKO\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/banadaranasr.co\" \/>\n<meta property=\"article:modified_time\" content=\"2017-09-27T08:44:27+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-01-300x195.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"http:\/\/banadaran.net\/en\/#website\",\"url\":\"http:\/\/banadaran.net\/en\/\",\"name\":\"BANADARAN ASR IKO\",\"description\":\"Official Website\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"http:\/\/banadaran.net\/en\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"http:\/\/banadaran.net\/%d9%85%d9%82%d8%a7%d9%84%d8%a7%d8%aa\/%d8%a7%d8%b4%d8%aa%d8%a8%d8%a7%d9%87%d8%a7%d8%aa-%d8%b1%d8%a7%db%8c%d8%ac-%d9%86%d8%b5%d8%a7%d8%a8%d8%a7%d9%86-%d9%87%d9%86%da%af%d8%a7%d9%85-%d9%86%d8%b5%d8%a8-%d9%82%d8%b3%d9%85%d8%aa-%d8%b3%d9%88\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"http:\/\/banadaran.net\/wp-content\/uploads\/2017\/09\/mistakes-03-01.jpg\",\"width\":404,\"height\":263},{\"@type\":\"WebPage\",\"@id\":\"http:\/\/banadaran.net\/%d9%85%d9%82%d8%a7%d9%84%d8%a7%d8%aa\/%d8%a7%d8%b4%d8%aa%d8%a8%d8%a7%d9%87%d8%a7%d8%aa-%d8%b1%d8%a7%db%8c%d8%ac-%d9%86%d8%b5%d8%a7%d8%a8%d8%a7%d9%86-%d9%87%d9%86%da%af%d8%a7%d9%85-%d9%86%d8%b5%d8%a8-%d9%82%d8%b3%d9%85%d8%aa-%d8%b3%d9%88\/#webpage\",\"url\":\"http:\/\/banadaran.net\/%d9%85%d9%82%d8%a7%d9%84%d8%a7%d8%aa\/%d8%a7%d8%b4%d8%aa%d8%a8%d8%a7%d9%87%d8%a7%d8%aa-%d8%b1%d8%a7%db%8c%d8%ac-%d9%86%d8%b5%d8%a7%d8%a8%d8%a7%d9%86-%d9%87%d9%86%da%af%d8%a7%d9%85-%d9%86%d8%b5%d8%a8-%d9%82%d8%b3%d9%85%d8%aa-%d8%b3%d9%88\/\",\"name\":\"Most common mistakes made by roofers \\u2013 part 3 - BANADARAN ASR IKO\",\"isPartOf\":{\"@id\":\"http:\/\/banadaran.net\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\/\/banadaran.net\/%d9%85%d9%82%d8%a7%d9%84%d8%a7%d8%aa\/%d8%a7%d8%b4%d8%aa%d8%a8%d8%a7%d9%87%d8%a7%d8%aa-%d8%b1%d8%a7%db%8c%d8%ac-%d9%86%d8%b5%d8%a7%d8%a8%d8%a7%d9%86-%d9%87%d9%86%da%af%d8%a7%d9%85-%d9%86%d8%b5%d8%a8-%d9%82%d8%b3%d9%85%d8%aa-%d8%b3%d9%88\/#primaryimage\"},\"datePublished\":\"2017-09-27T08:35:05+00:00\",\"dateModified\":\"2017-09-27T08:44:27+00:00\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/banadaran.net\/%d9%85%d9%82%d8%a7%d9%84%d8%a7%d8%aa\/%d8%a7%d8%b4%d8%aa%d8%a8%d8%a7%d9%87%d8%a7%d8%aa-%d8%b1%d8%a7%db%8c%d8%ac-%d9%86%d8%b5%d8%a7%d8%a8%d8%a7%d9%86-%d9%87%d9%86%da%af%d8%a7%d9%85-%d9%86%d8%b5%d8%a8-%d9%82%d8%b3%d9%85%d8%aa-%d8%b3%d9%88\/\"]}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"http:\/\/banadaran.net\/en\/wp-json\/wp\/v2\/pages\/1712"}],"collection":[{"href":"http:\/\/banadaran.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/banadaran.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/banadaran.net\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/banadaran.net\/en\/wp-json\/wp\/v2\/comments?post=1712"}],"version-history":[{"count":3,"href":"http:\/\/banadaran.net\/en\/wp-json\/wp\/v2\/pages\/1712\/revisions"}],"predecessor-version":[{"id":1735,"href":"http:\/\/banadaran.net\/en\/wp-json\/wp\/v2\/pages\/1712\/revisions\/1735"}],"up":[{"embeddable":true,"href":"http:\/\/banadaran.net\/en\/wp-json\/wp\/v2\/pages\/1312"}],"wp:attachment":[{"href":"http:\/\/banadaran.net\/en\/wp-json\/wp\/v2\/media?parent=1712"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}